Model
|
Power
(kW)
|
Output
(Amps)
|
Supply
|
Constant
Torque
|
Fan
and
Pump
|
Constant
Torque
|
Fan
and
Pump
|
|
J300
055 HFE
|
5.5
|
7.5
|
13
|
16
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
075 HFE
|
7.5
|
11
|
16
|
23
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
110 HFE
|
11
|
15
|
23
|
30
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
150 HFE
|
15
|
22
|
32
|
44
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
220 HFE
|
22
|
30
|
48
|
59
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
300 HFE
|
30
|
37
|
58
|
74
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
370 HFE
|
37
|
45
|
75
|
88
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
450 HFE
|
45
|
55
|
90
|
108
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
550 HFE
|
55
|
75
|
110
|
146
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
750 HFE
|
75
|
90
|
149
|
176
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
900 HFE
|
90
|
110
|
176
|
217
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
J300
1100 HFE
|
110
|
132
|
217
|
260
|
Three-phase
380-460V +/-10%
50-60Hz +/-5%
|
|
Control System |
Sensorless Flux Vector |
|
Output Frequency Range |
0.1 to 400Hz |
|
Overload Rating Constant Torque |
150% for 1 minute |
|
Overload Rating Fan and Pump |
115% for 30 seconds |
|
Frequency Resolution |
0.01Hz |
|
Starting Torque |
150% (minimum) @ 1Hz |
|
Braking |
By external unit |
|
DC Injection Braking |
Independant setting for power, time, frequency |
|
Speed Reference |
Digital, 0-5V, 0-10V, 4-20mA |
|
Multi Stage Speed |
8 Pre-sets |
|
Output Voltage |
Auto Voltage Regulation AVR |
|
Acceleration |
0.01-3000s linear or S ramp - 2 selectable |
|
Deceleration |
0.01-3000s linear or S ramp - 2 selectable |
|
Input Terminals |
8 programmable terminals from 28 slections |
|
Output Terminals |
2 programmable terminals from 4 selections |
|
Drive Status |
Status Relay |
|
Meter Output |
Volt output for speed & load |
|
Carrier Frequency |
2-16KHz |
|
Dual Motors |
2nd set of motor functions |
|
Fuzzy Logic |
Standard |
|
Auto Tuning |
Standard |
|
Load Rating |
Constant torque / Fan & pump ratings |
|
Auto Energy Saving |
Standard |
|
Protection |
26 functions inc. earth fault |
|
Trip History |
Last 3 trips, total trip log & run time since last trip |
|
Ambient Temperature |
-10°C to 50°C |