Model
Power (kW)
Output (Amps)
Supply
Constant
Torque
Fan and
Pump
Constant
Torque
Fan and
Pump
J300 055 HFE
5.5
7.5
13
16
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 075 HFE
7.5
11
16
23
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 110 HFE
11
15
23
30
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 150 HFE
15
22
32
44
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 220 HFE
22
30
48
59
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 300 HFE
30
37
58
74
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 370 HFE
37
45
75
88
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 450 HFE
45
55
90
108
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 550 HFE
55
75
110
146
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 750 HFE
75
90
149
176
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 900 HFE
90
110
176
217
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J300 1100 HFE
110
132
217
260
Three-phase
380-460V +/-10%
50-60Hz +/-5%

Control System Sensorless Flux Vector
Output Frequency Range 0.1 to 400Hz
Overload Rating Constant Torque 150% for 1 minute
Overload Rating Fan and Pump 115% for 30 seconds
Frequency Resolution 0.01Hz
Starting Torque 150% (minimum) @ 1Hz
Braking By external unit
DC Injection Braking Independant setting for power, time, frequency
Speed Reference Digital, 0-5V, 0-10V, 4-20mA
Multi Stage Speed 8 Pre-sets
Output Voltage Auto Voltage Regulation AVR
Acceleration 0.01-3000s linear or S ramp - 2 selectable
Deceleration 0.01-3000s linear or S ramp - 2 selectable
Input Terminals 8 programmable terminals from 28 slections
Output Terminals 2 programmable terminals from 4 selections
Drive Status Status Relay
Meter Output Volt output for speed & load
Carrier Frequency 2-16KHz
Dual Motors 2nd set of motor functions
Fuzzy Logic Standard
Auto Tuning Standard
Load Rating Constant torque / Fan & pump ratings
Auto Energy Saving Standard
Protection 26 functions inc. earth fault
Trip History Last 3 trips, total trip log & run time since last trip
Ambient Temperature -10°C to 50°C