Model
Power (kW)
Output (Amps)
Supply
J100 004 SFE
0.55
3
Single-phase
200-240V +/-10%
50-60Hz +/-5%
J100 007 SFE
0.75
5
Single-phase
200-240V +/-10%
50-60Hz +/-5%
J100 015 SFE
1.5
7.5
Single-phase
200-240V +/-10%
50-60Hz +/-5%
J100 022 SFE
2.2
10.5
Single-phase
200-240V +/-10%
50-60Hz +/-5%

Model
Power (kW)
Output (Amps)
Supply
J100 015 HFE
1.5
3.8
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J100 022 HFE
2.2
5.3
Three-phase
380-460V +/-10%
50-60Hz +/-5%
J100 037 HFE
4.0
8.6
Three-phase
380-460V +/-10%
50-60Hz +/-5%

Control System Sensorless Flux Vector
Output Frequency Range 0.5 to 360Hz
Overload Rating 150% for 1 minute
Frequency Resolution 0.01Hz
Starting Torque 150% (minimum) @ 3Hz
Braking Built in transistor, external resistor
DC Injection Braking Independant setting for power, time, frequency
Speed Reference Digital, 0-5V, 0-10V, 4-20mA
Multi Stage Speed 8 Pre-sets
Output Voltage Auto Voltage Regulation AVR
Acceleration 0.5-3000s linear or S ramp - 2 selectable
Deceleration 0.5-3000s linear or S ramp - 2 selectable
Input Terminals 5 programmable terminals from 13 selections
Output Terminal 1 programmable terminal from 3 selections
Drive Status Status Relay
Meter Output Volt output for speed & load
Carrier Frequency 5-16KHz
Dual Motors 2nd set of motor functions
Protection 14 functions inc. earth fault
Trip History Last 3 trips, total trip log
Ambient Temperature -10°C to 50°C